Gartner shares data center efficiency secrets

Gartner's eleven top tips for reducing power consumption are...

Power consumption at data centers is once again in the spotlight, after analyst house Gartner came up with a list of best practices in the data center, designed to save electricity and improve cooling.

Gartner modestly claims that if companies follow all of its best practices, it could typically expect to save one million kilowatt hours. It says that in a conventional data center, between 35 and fifty percent of the electricity consumed is for cooling compared to only 15 percent in best practice or 'green' data centers.

"Virtually all data centers waste enormous amounts of electricity using inefficient cooling designs and systems," said Paul McGuckin, research vice president at Gartner in a statement. "Even in a small data center, this wasted electricity amounts to more than 1 million kilowatt hours annually that could be saved with the implementation of some best practices."

The main reason for the waste in conventional data center cooling is the "unconstrained mixing of cold supply air with hot exhaust air."

"This mixing increases the load on the cooling system and energy used to provide that cooling, and reduces the efficiency of the cooling system by reducing the delta-T (the difference between the hot return temperatures and the cold supply temperature). A high delta-T is a principle in cooling," McGuckin said.

Gartner's eleven top tips for reducing power consumption are:

-- Plug holes in raised floor. This point was also raised by SunGard Availability Services last month, as apparently holes in the floor allows cold air to escape and mix with hot air. This single low-tech retrofit can save as much as 10 percent of energy used for data center cooling, says Gartner.

-- Installing blanking panels. Data centers are full of racks, and unused rack space needs to be covered with a blanking panel so that airflow can be properly managed, for example by preventing hot air leaving equipment in one section of the rack and then entering the cold air intake for other equipment elsewhere in the rack. Gartner says when these panels are used effectively; supply air temperatures can be lowered by as much as 22 degrees Fahrenheit (or minus 5 degrees Celsius).

-- Co-ordinate CRAC units. A CRAC unit (according to Gartner) is an older Computer Room Air-conditioning Unit (CRAC). Apparently these units operate independently of each other when cooling and dehumidifying the air. Gartner suggests that if these units could be tied together with newer technologies, and their efforts coordinated, then the results would be a much more efficient cooling system.

-- Improve underfloor airflow. This typically affects older data centers, where the space under the raised flooring is a lot more constrained than newer builds. Many old data centers also use the underfloor spacing for running data and power cables, thereby restricting airflow. A clear out of these spaces is advised.

-- Implement hot and cold aisles. This is one of the most obvious best practices. Gartner says traditional data centers use a "classroom style" to position their racks, whereby all the intakes face in one direction. The problem with this setup is that hot air exhausted from one row, mixes with cold air being drawn into the adjacent row, thereby increasing cold-air supply temperature in uneven ways. Newer rack layout practices over the last ten years instead organize rows into hot and cold aisles, which offering much better control of air flow.

-- Install sensors. Seems obvious, but how do you tell if you have a temperature problem in a certain area of your data center? Gartner says a minimal investment in this technology could reap big insights into data center operations and can also provide a method for analyzing the results of improvements made to the cooling systems.

-- Implement cold or hot aisle containment. When a data center uses hot and cold aisles, dramatically improved separation of cold supply air and hot exhaust air through containment becomes a viable option. Gartner reckons effective containment of the hot or cold aisles will be, for most users, the single largest payback of any of these best practices.

-- Raise the temperature in the data center. Most data centers are run too cold, and raising the temperature by a few degrees often will not affect the equipment.

-- Install variable speed fans and pumps. Traditional CRAC units run at a single speed, but a variable speed fan should be used rather. A reduction of 10 percent in fan speed, apparently yields a reduction in fan electrical consumption of roughly 27 percent. Reducing fan speed by 20 percent yields electrical savings of approximately 49 percent.

-- Exploit free cooling. Depends a lot on local climate, but in winter in the UK, cold air is readily available outside the data center.

-- Designing new data centers using modular cooling. Traditional data centers have been cooled by the raised floor perimeter air distribution. Mounting evidence strongly points to the use of modular cooling (in-row or in-rack) as a more energy efficient cooling strategy.

Additional information can be found in a Gartner report, "How to Save a Million Kilowatt Hours in your Data Center."

Join the newsletter!

Or

Sign up to gain exclusive access to email subscriptions, event invitations, competitions, giveaways, and much more.

Membership is free, and your security and privacy remain protected. View our privacy policy before signing up.

Error: Please check your email address.

Tags data center power consumption

Keep up with the latest tech news, reviews and previews by subscribing to the Good Gear Guide newsletter.

Tom Jowitt

Techworld
Show Comments

Father’s Day Gift Guide

Brand Post

Bitdefender 2019

Bitdefender solutions stop attacks before they even begin! Get cybersecurity that 500 MILLION users already have and trust.

Most Popular Reviews

Latest Articles

Resources

PCW Evaluation Team

Luke Hill

MSI GT75 TITAN

I need power and lots of it. As a Front End Web developer anything less just won’t cut it which is why the MSI GT75 is an outstanding laptop for me. It’s a sleek and futuristic looking, high quality, beast that has a touch of sci-fi flare about it.

Emily Tyson

MSI GE63 Raider

If you’re looking to invest in your next work horse laptop for work or home use, you can’t go wrong with the MSI GE63.

Laura Johnston

MSI GS65 Stealth Thin

If you can afford the price tag, it is well worth the money. It out performs any other laptop I have tried for gaming, and the transportable design and incredible display also make it ideal for work.

Andrew Teoh

Brother MFC-L9570CDW Multifunction Printer

Touch screen visibility and operation was great and easy to navigate. Each menu and sub-menu was in an understandable order and category

Louise Coady

Brother MFC-L9570CDW Multifunction Printer

The printer was convenient, produced clear and vibrant images and was very easy to use

Edwina Hargreaves

WD My Cloud Home

I would recommend this device for families and small businesses who want one safe place to store all their important digital content and a way to easily share it with friends, family, business partners, or customers.

Featured Content

Product Launch Showcase

Don’t have an account? Sign up here

Don't have an account? Sign up now

Forgot password?